Items/Model TS50(PLC) Burn Rate Average 50 kg/hour Feed Capacity Average 50kg Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14.0 – 28.0 Gas Consumption (m3/hour) 10.0 – 32.2 Temperature Monitor Yes Temperature Protection Yes Oil Tank 100L […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS50(PLC) Burn Rate Average 30 kg/hour (*animal) Feed Capacity Average 50kg (*animal) Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature […]
Nanjing Clover Medical technology Co.,Ltd. is a leading waste incinerator manufacturer in China, the incinerator for hospital medical waste incineration, pets and animal cremation, other solid waste incineration treatment.
Three sets incinerator with 1oo kgs per hour capacity dispatch to Africa customer.
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
Clover Incinerator supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour and 50kgs per hour. We are famous small scale incinerator […]
a.) incinerator for waste. VS cremator for animals b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns. c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation is personal business more. f.) waste […]
We are ready to send new Waste incinerator for Ethiopia. We arrange all shipping to Djibouti port. This shipping delivery with CIQ(CHINA ENTRY-EXIT INSPECTION AND QUARANTINE), Chamberized Commercial Invoice, CO, etc document/certification. See video show this web link: https://vimeo.com/235864206 Model YD300 Burning Rate Average 300 kgs/hour Feed Capacity Average 500 kgs Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters […]
diesel oil burner for incinerators WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com
Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more […]
1. Clover Medical Limited save all rights to mend/update product information on website. The specifications are subject to change without prior notice. 2. We accept business term: FOB/C&F/CIF term, by sea/train, full container or bulk goods. 1. FOB (Free on Board), the price leave China port. 2. C&F (Cost and Freight), FOB price and freight […]
New continued feeding incinerator is valid for large scale incinerator, main function including a.)waste feeding system, b.)incinerator mainbody, c.)wet scrubber system. Burning rate up to 500kgs per hour and 4.7m3 primary combustion chamber capacity. Waste Auto-Feeding →→ Shredder System→→ Primary Combustion Chamber→→ Mix & Secondary Combustion Chamber Wet Spray Scrubber→→ Wet Dust Scrubber→→ Cyclone Filter […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
We delivery small scale incinerator to Haiti and kindly customer send back the local photo. Items/Model YD-20C Burning Rate (kgs/Hour) Average 20 kgs/Hr. Feed Capacity (kgs) Average 40 kgs Equipment Weight 2100 kgs Primary Chamber (Liters) 200 Secondary Chamber (Liters) 140 External Dimensions (cm) 170x140x160 Internal Dimensions (cm) Dia.55×65 Oil Tank(Liters) 100 Door Opening (cm) […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed and destroyed in an appropriate manner. With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS50(PLC) Burn Rate Average 30 kg/hour (*animal) Feed Capacity Average 50kg (*animal) Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature […]
Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc. The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until […]
Technicians from CLOVER are available to supervise customer’s skilled staff for installation, commissioning, train customer’s technical and production staff and help the staff to produce qualified end product. Clover’s engineers mission is operate or direct customer’s worker how to do. Local customer have to supply necessary equipment and local engineers or workers. Pease note that […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
Basic Info. Type:Medical Waste Incinerator Export Markets:Global Additional Info. Trademark:clover Product Description Main Characteristics: 1, Utilizing fever of gasifying unites burning technology. It applied to burn off several kinds of medical waste, like syringes, infusion set, medical waste incinerator supplier, medical equipment makers, medicine waste in china, mobile toxic waste incinerators, mobile incinerator medical waste, […]
Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features: Product List Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel) […]
There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several construction sites and all fuel type is diesel oil.
MOGADISHU SOMALIA WASTE INCINERATOR TREATMENT – TS300( PLC) Incinerator Items/Model HICLOVER TS300(PLC) Burn Rate (Average) 300 kg/hour Feed Capacity(Average) 400kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 2000Liters(2.0m3) Internal Dimensions 1700x1200x1000mm Secondary Chamber 1000Liters(1.0m3) Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 28 N.Gas Consumption […]
Advantages of Waste Incineration Decreases Quantity of Waste. … Efficient Waste Management. … Production of Heat and Power. … Reduction of Pollution. … Incinerators Have Filters For Trapping Pollutants. … Saves on Transportation of Waste. … Provides Better Control Over Odor […]
Basic Info. Model NO.:medical waste incinerators on sales Export Markets:Global Product Description Technology Respond(FAQ) Q: What’s kind of waste may use in this gear? A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid gas and waste waste. Q: Incinerator Smoke Standard A: China Government Standard: […]
Product Description Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, extended lifetime. *based on order * High temperature, long lifetime of incinerator. * Free or minimal installation onsite. * High burn rate, from 10kgs to 500kgs per hourto 6ton daily. * PLC Control Plane. *based on order New Design for […]
Basic Info. Model NO.:cost of an incinerator with 20kg/hr loading rate Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Technology Respond(FAQ) Q: What’s kind of waste can use in this gear? A: This gear to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid gas and waste […]
Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals. Construction is dual/double combustion chamber with 03 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). Primary & Secondary combustion chambers and included mix-combustion chamber, smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load […]
Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste. HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: sales@hiclover.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. 2020-07-21
High-Temperature Animal Waste Incineration Systems for Food Processing and Cold Chain Centers Food processing and cold chain facilities―including slaughterhouses, seafood factories, and food storage hubs―generate complex waste streams such as animal carcasses, oily residues, and contaminated packaging materials. In regions like Southeast Asia, Africa, and South America, these operations are vital to food security yet […]
Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:6.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 04 sets Oil Tank (if oil fuel): 800Liters The secondary chamber must comply with the following minimum criteria: “• Heavy steel construction small scale incinerators incinerator burner • An excess air and high temperature operational mode. • Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated. • Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times. • Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. • Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. • Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints • An electrically powered fan forced air supply, with the capacity for variation by the operator. • One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter. • A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner. Medical Waste Incineration Treatment Average 1000-1500 kg/hour Average 6000kg/feeding PLC(Programmable Logic Controller Incinerator) 4800Liter A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended. The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content. “The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment. All incinerators shall meet the following emission and operating standards: • Combustion efficiency (C.E.) shall be at least 99.0% • The combustion efficiency shall be computed as follows: • The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less than 10 metres per second vertically upwards when at full scale operation. • An emission stack sampling port shall be included immediately above the secondary chamber. ” Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator. “Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each. • The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator. The pumping system will have two pumps in parallel for redundancy. • The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line. • The unit shall be equipped with a fuel meter. “Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid) The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports. The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour). “The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables: • A first aid kit, suitable for addressing the hazards presented by the unit. • 5 full sets of personal protective clothing and equipment. • Operating logbooks. […]
The new plant could help in reducing energy losses in the incineration process as well as reducing harmful emissions Wasteserv inaugurated a $12 million animal waste management in Marsa earlier now. Speaking at the inauguration of the new Wateserv EU-funded autoclave producing plant for the treatment of animal waste, Wasteserv CEO Tonio Montebello reported that […]
News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed […]
Basic Info. Type:Incinerator Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs Primary Chamber […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Origin:Pr China Production Capacity:1000 Sets Per Year Product Description 2.
Model CA50 Picture Waste Treatment Waste Incineration Treatment Feed Capacity Average 100 kgs per feed Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 0.7Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption (Oil) […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Model TS30 PLC Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 sets Oil Tank (if oil fuel): 100Liters