Q: What’s kind of waste may use in this gear? A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time per day is about 16 hours. The life of incinerator involving 5-10 year according to use.
Ordinarily, we proposition small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please compute the waste output around 2kgs per individuals every day. If there are 200 sickbed at the clinic, that's imply you need one incinerator capacity around 400kgs every day, change to capacity per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you may use capacity from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators simple to installation and operation. Client can send individuals visit our factory to find out operation and installation. Waste+incinerator+maker, animal cremation, animal crematory equipment, animal incinerator price, animal incinerator maker, cheap incinerators, Ordinarily, we don’t send engineer to local site or even ask. The dispatch price is additional according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation price according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One individual can service 02 device incinerators. The team should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and understand threat of medical waste to safeguard worker self with necessary protection component.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |