The chamber should be insulated and refractory lined with high temperature and heat resistant material.
Should be fitted with burners that use low sulphur fuel.
Auxiliary air supply should be controlled.
Ensure residence time is not less than two seconds.
Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is
not less than 1100 degrees centigrade.
Ensure the emitted oxygen content of the emitted gases is not less than 11%
Ensure both primary and secondary combustion temperatures are maintained until all waste is completely combusted.
Heat input from the afterburner should be controlled automatically by the programmable digital control system, such that
in the event of temperatures in excess of 950°C – 1,050°C being transferred from the primary chamber the afterburner
will switch off to conserve fuel.
Provide 2 burners- 1 diesel fired packaged primary burner and a single secondary afterburner.
The burners should be temperature controlled to conserve fuel and attain optimum combustion.
Factory waste disposal packed unit dim 1850mm*2000mm*2500mm incinerator capable of burning a guaranteed 50 kg/hr of
office waste efficiently without the emission of fly ash, dour and smoke
-Refuse ignition burner
– After burner
-Air fans
-Refractory lined steel shell with integrated ducts
Auxiliary air supply should be controlled.
Ensure residence time is not less than two seconds.
Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is
not less than 1100 degrees centigrade.
Ensure the emitted oxygen content of the emitted gases is not less than 11%
Ensure both primary and secondary combustion temperatures are maintained until all waste is completely combusted.
Heat input from the afterburner should be controlled automatically by the programmable digital control system, such that
in the event of temperatures in excess of 950°C – 1,050°C being transferred from the primary chamber the afterburner
will switch off to conserve fuel.
Provide 2 burners- 1 diesel fired packaged primary burner and a single secondary afterburner.
The burners should be temperature controlled to conserve fuel and attain optimum combustion.
Factory waste disposal packed unit dim 1850mm*2000mm*2500mm incinerator capable of burning a guaranteed 50 kg/hr of
office waste efficiently without the emission of fly ash, dour and smoke
-Refuse ignition burner
– After burner
-Air fans
-Refractory lined steel shell with integrated ducts
Primary combustion chamber with a capacity of 1 cubic meters.
Stainless steel chimney > 6 meters.
Burn rate (rate of waste incineration) -at least 50 kg per hour
Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing
ash.
1 off diesel-fired ignition burner C temperature controlled
1 off combustion air supply fan and distribution system
High capacity secondary combustion chamber 2.0 @ >1050oC
1 off diesel-fired afterburner C temperature controlled
Stainless steel chimney > 6 meters.
Burn rate (rate of waste incineration) -at least 50 kg per hour
Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing
ash.
1 off diesel-fired ignition burner C temperature controlled
1 off combustion air supply fan and distribution system
High capacity secondary combustion chamber 2.0 @ >1050oC
1 off diesel-fired afterburner C temperature controlled