Basic Info. Model NO.:incinerator double chamber 100kg per hour manufac Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Items/Model YD-200 YD-300 YD-500 YD-600 Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs […]
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Model YD-50 Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs Primary Combustion Chamber 900 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke […]
Product Description Key Features: * All versions with Dual combustion room. *according to sequence * High temperature, long life of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hourto 6ton per day. *according to order * New Design for pet animal cremation business. * One year […]
Model CA50 Feed Capacity Average 60 kgs per feed Burning Rate Average 70 kgs per hour Burning Time per Feed 1 hour Voltage 220V Power 0.7Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) Average 18 Kgs/Hour Internal Dimensions 100x80x70cm (Primary Chamber) External Dimensions 230 x 130 x 155cm (main body) […]
Basic Info. Model NO.:construction of fire brick incinerator Export Markets:Global Product Description Technology Respond(FAQ) Q: What’s kind of waste can use in this equipment? A: This equipment for medical waste, pet creature, Municipal waste, reside waste. Prohibit any explosive and radiation material, liquid gas and waste waste. Q: Incinerator Smoke Standard A: China Government Standard: […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: sales@hiclover.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional
Model CA50 Picture Waste Treatment Waste Incineration Treatment Feed Capacity Average 50 kgs per feed Burning Rate Average 100 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 0.7Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption (Oil) […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Origin:Cn Production Capacity:1000 Sets Per Year Product Description We supply incinerator and also burners. Some model of incinerator use Italy original burner (gas or oil fuel) and some model use China original burner. Generally, incinerator with two burners but we can add […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless […]
Basic Info. Export Markets:Global Product Description Key Features: * All models with Dual combustion chamber. *according to order * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical Technology Co., Ltd.. Clover Medical supply medical incinerator, ability from 10kgs per hour to 500kgs per hour. China clover medical, china companies incinerator, china cremation incinerator, china crematorium manufacturers, china disagreements over health effects from waste incineration, Items/Model YD-10C YD-20C YD-30C YD-50C Burning […]
Incinerator Model YD-30 for Australia Melbourne customer. From year 2011 to 2013, we delivery 02 different model for this customer, one is model SYC-50 (now updated to Model TS50 PLC) and one model YD-30. Both two model is gas fuel type and these incinerator for local family pet cremation business.
Items/Model TS2000 (Top Feeding) Principle Waste Incineration Treatment Burn Rate Average 500-600kg/hour Feed Capacity Average 4500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 7700Liter (7.7m3) Internal Dimensions 5000*1400*1100 mm Secondary Chamber 4000Liter (4.0m3) Feed Mode Manual/Forklift/Crane Description Brand Model Fuel Type Waste Incinerator HICLOVER TS2000 Oil/Gas *Primary combustion chamber *Secondary combustion chamber * Stainless Steel chimney *Auto PLC control system *Italy brand burner * Automatic Protection Operator(APO) *Heavy duty refractory chamber *Corundum […]
Basic Info. Export Markets:Global Product Description How you are able to find reasonable incinerator to your regional website? Incinerator isn’t a cheap equipment, normally the little scale version 's cost around $5, 000usd per unit and big scale version 's cost more than $50, 000usd each unit. Incinerator is a incineration equipment, function is fire […]
Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:6.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 04 sets Oil Tank (if oil fuel): 800Liters The secondary chamber must comply with the following minimum criteria: “• Heavy steel construction small scale incinerators incinerator burner • An excess air and high temperature operational mode. • Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated. • Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times. • Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. • Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. • Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints • An electrically powered fan forced air supply, with the capacity for variation by the operator. • One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter. • A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner. Medical Waste Incineration Treatment Average 1000-1500 kg/hour Average 6000kg/feeding PLC(Programmable Logic Controller Incinerator) 4800Liter A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended. The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content. “The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment. All incinerators shall meet the following emission and operating standards: • Combustion efficiency (C.E.) shall be at least 99.0% • The combustion efficiency shall be computed as follows: • The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less than 10 metres per second vertically upwards when at full scale operation. • An emission stack sampling port shall be included immediately above the secondary chamber. ” Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator. “Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each. • The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator. The pumping system will have two pumps in parallel for redundancy. • The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line. • The unit shall be equipped with a fuel meter. “Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid) The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports. The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour). “The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables: • A first aid kit, suitable for addressing the hazards presented by the unit. • 5 full sets of personal protective clothing and equipment. • Operating logbooks. […]
Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed and destroyed in an appropriate manner. With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of […]