Waste Incinerator

Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Program Scope:  1. Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi gas. As distinct circumscription, incinerator can be named many words as under:  Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant.  Waste substance: Municipal waste incinerator, medical waste […]
Mobile Small Scale Medical Waste Incinerator with Trolley(E-Power) or Wheel Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel […]
TS100 incinerator exert the advantages and discard the disadvantages of  the same kind of equipment at domestic and abroad. It is an unique and  international advanced incineration equipment. The equipment is small size,  high efficiency, reasonable process, leading technologies and a high  harmless degree, ideal garbage treatment equipment for farm, hospital,  laboratory, hotel, station, etc. […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Key Attributes:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *based on […]
Items/Model TS50(PLC) Principle Animal Cremation Treatment Burn Rate Average 25 kg/hour Feed Capacity Average 50kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature Monitor Digital Display Temperature Protection […]
Incinerator Model YD-150, Overview This model is middle-scale waste incineration equipment for middle waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1500Liters (1.5m3, YD-150). Primary &  Secondary combustion chambers and included mix-combustion chamber, smoke filter  chamber and Refractory Concrete chamber. Batch load on […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion chamber.  *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control […]
Basic Info. Model NO.:TS30 PLC Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Packing:Full Container Standard:30 kg per hour Origin:China Production Capacity:1000 Sets Per Year Product Description   Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator maker in China. We are local  producer and among the largest exporter of […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
Incinerator units shall include an integral and mechanized bottom ash removal system.Ali the measuring devices attached to the incinerator should have digital display and should have  provision of connecting to the recording system, which should include fuel meter and separate energy meter.Include designed pollution control devices such as scrubbers, filters or electrostatic precipitators to achieve emission limits.Each unit shall include a complete vertical exhaust and stack system 6-12 m above ground level with exhaust exit velocity of not less than 10 meters per second.Include clearly readable system operation panels. Spare parts:Each incinerator shall be supplied with all necessary spare parts required for two (2) years of operation (one set for each unit).Mandatory spare parts, for all the incinerators as a minimum, shall include: thermocoupletemperature gaugefire ropeburnerinduction air fandigital temperature display panel
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour  Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L Smoke Filter Chamber Optional Feed […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.com Email: hicloversales@gmail.com   Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour Feed Capacity Average 250kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1300L Internal Dimensions 120x100x110cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption […]
Basic Info. Model NO.:medical waste incinerator manufacturer Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units […]
having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust.   Optional 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator. […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com  
Mobile Containerized Waste Incinerators pets or human cremation emergency use   Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x […]
Main Characteristics: 1, Using fever of gasifying unites burning technology. It applied to burn various  kinds of medical waste, such as syringes, infusion set, disposable dressing, and also  small animal, some city waste, like paper, tree leaves. 2, Closed vacuum-wide operation, applicable to treat infectious medical waste and  to prevent secondary pollution. 3, Whole design, […]
Incinerator Model TS50 PLC, Overview This model is small-scale animal cremation equipment for small – middle animal.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 560Liters (0.56m3, TS50 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. […]
a) lncineration capacity: 75 kg/hr.– up to 100kgs/hour b) Number of combustion chamber: Two (02)—yes c) Operating temperature in primary chamber: 850±50 °C— 800°C-1000°C d) Operating temperature in secondary chamber: 1200±50 °C— 1000°C-1300°C e) Burner type: Pressure jet diesel fired—yes f) Power system: Three phase, 50 Hz, 380 – 440  VAC—yes g) MOC: Vendor to […]
Basic Info. Model NO.:MSW4000 Export Markets:Global Additional Info. Trademark:CLOVER Product Description We are among the largest waste incinerator manufacturer and exporter of China. Pyrolytic incinerator specialized is primary waste treatment system all over the world, environmental incinerator, economical cremation equipment for creatures, economical incinurater, edical incinerator, electric incinerator 100kg, for Medical Waste, Animal Incineration, Pet […]
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts