Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

We delivery  small scale incinerator to Haiti and kindly customer send back the local photo. Items/Model YD-20C Burning Rate (kgs/Hour) Average 20 kgs/Hr. Feed Capacity (kgs) Average 40 kgs Equipment Weight 2100 kgs Primary Chamber (Liters) 200 Secondary Chamber (Liters) 140 External Dimensions (cm) 170x140x160 Internal Dimensions (cm) Dia.55×65 Oil Tank(Liters) 100 Door Opening (cm) […]
Nanjing Clover Medical technology Co.,Ltd. is a leading waste incinerator manufacturer in China, the incinerator for hospital medical waste incineration, pets and animal cremation, other solid waste incineration treatment.
1. Clover Medical Limited save all rights to mend/update product information on website. The specifications are subject to change without prior notice. 2. We accept business term: FOB/C&F/CIF term, by sea/train, full container or bulk goods. 1. FOB (Free on Board), the price leave China port. 2. C&F (Cost and Freight), FOB price and freight […]
New continued feeding incinerator is valid for large scale incinerator, main function including a.)waste feeding system, b.)incinerator mainbody, c.)wet scrubber system. Burning rate up to 500kgs per hour and 4.7m3 primary combustion chamber capacity. Waste Auto-Feeding →→ Shredder System→→ Primary Combustion Chamber→→ Mix & Secondary Combustion Chamber Wet Spray Scrubber→→ Wet Dust Scrubber→→ Cyclone Filter […]
Average 20%-25% of the total waste generated by healthcare establishments is  regarded as hazardous and may create a variety of health and environmental risks  if not managed and destroyed in an appropriate manner. With years worth of experience in this sector, our medical range of incinerators are  designed to cater for the economical needs of […]
Three sets incinerator with 1oo kgs per hour capacity dispatch to Africa customer.
Items/Model TS50(PLC) Burn Rate Average 50 kg/hour Feed Capacity Average 50kg Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14.0 – 28.0 Gas Consumption (m3/hour) 10.0 – 32.2 Temperature Monitor Yes Temperature Protection Yes Oil Tank 100L […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS50(PLC) Burn Rate Average 30 kg/hour (*animal) Feed Capacity Average 50kg (*animal) Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature […]
Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more […]
Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.   The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator […]
Clover Incinerator supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour and 50kgs per hour. We are famous small scale incinerator […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator […]
Technicians from CLOVER are available to supervise customer’s skilled staff for installation, commissioning, train customer’s technical and production staff and help the staff to produce qualified end product. Clover’s engineers mission is operate or direct customer’s worker how to do. Local customer have to supply necessary equipment and local engineers or workers. Pease note that […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa,  Middle East, Southeast Asia countries and part of North America, Europe territory.  We are trusted partner for governmental organizations, non-profit organizations,  international contractors, logistics organizations, military, pet cremation business  owners, etc. We have export experience more than 40 countries,  including […]
diesel oil burner for incinerators WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com  
a.) incinerator for waste. VS cremator for animals b.) incineration to be ash and clean it. VS cremation and collect ash into pet cremation urns. c.) waste stack disorderly.VS pet in chamber individual. d.) waste material complicated. VS pet is body. e.) waste incineration is public affairs. VS pet cremation is personal business more. f.) waste […]
We are ready to send new Waste incinerator for Ethiopia. We arrange all shipping to Djibouti port. This shipping delivery with CIQ(CHINA ENTRY-EXIT INSPECTION AND QUARANTINE), Chamberized Commercial Invoice, CO, etc document/certification. See video show this web link: https://vimeo.com/235864206 Model YD300  Burning Rate Average 300 kgs/hour Feed Capacity Average 500 kgs Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS50(PLC) Burn Rate Average 30 kg/hour (*animal) Feed Capacity Average 50kg (*animal) Control Mode PLC Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature […]
Incinerator Model CA100 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1200Liters (1.2m3, CA100 ).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description How you are able to find reasonable incinerator for your regional website?  Incinerator isn’t a cheap equipment, normally the little scale version 's cost around $5, 000usd per unit and large scale version 's price greater than $50, 000usd each […]
Key Word: small incinerators medical waste incinerator pet animal cremation incinerator incinerator manufacturers     Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:   Treatment capacity: small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal […]
Nanjing Clover Medical Technology Co.,Ltd. • Also consider provision for meeting international emission standards. Able to handle an average waste production of 100kg/day “• Minimum load capacity: 20 kg • Maximum load capacity: 40 kg • Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day) The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections The forecasted feedstock loads, and daily loading rates are generally summarized as: • Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities.   The wastes will consist of 100% biomedical wastes. • Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size. • Operation on a daytime shift basis, 5 days per week. • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion  Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion, etc.o C.E = (CO2 X 100) / (%CO2 +%CO) incinerator price incinerator for medical waste Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.” “Each unit shall include a complete vertical exhaust and stack system, including the following features: • Steel construction. The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. • Refractory lining in the lower section. • The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on the capacity of the incinerator unit.  The incinerator shell shall be made of mild steel with an adequate thickness for small units of between 3-6mm and larger units 5-10 mm depending on the construction part and painted externally with heat resistant aluminum paint suitable to withstand 250° C.  The outside surface temperature of the incinerator casing should not exceed 50° C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100 mm.  The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations. “The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle.  e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. g. include clearly readable system operation panels. h. include an operator’s manual (in English and French and Spanish). i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding. j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated. k. can accommodate large variations in waste composition and calorific value. l. allow for batch loading The control system shall include an electronic performance monitoring and logging system. The system shall be capable of monitoring and logging chamber temperatures at regular intervals (not less than once per minute, with the capacity to vary the logging frequency). The system shall include the capacity to download the performance data by USB connection.  All the measuring devices attached with the incinerator should have digital display and should have provision of connecting to the recording system, which should include fuel meter and separate energy meter. The temperature shall be determined against the inside wall of the combustion chambers. An audible and visible alarm shall be installed to warn the operator when the secondary temperature drops to below the required temperature. The primary chamber must meet or exceed the following criteria: • Multiple electric ignition fuel burners designed to use automotive diesel fuel. • Flame of the primary burner shall be oriented towards the center of the unit which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.  • The unit shall prevent leakage of the hot flue gas and any backfire.  […]
Mobile Small Scale Medical Waste Incinerator with Trolley(E-Power) or Wheel Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel […]
Product Description Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
TS100 incinerator exert the advantages and discard the disadvantages of  the same kind of equipment at domestic and abroad. It is an unique and  international advanced incineration equipment. The equipment is small size,  high efficiency, reasonable process, leading technologies and a high  harmless degree, ideal garbage treatment equipment for farm, hospital,  laboratory, hotel, station, etc. […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Key Attributes:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *based on […]
Items/Model TS50(PLC) Principle Animal Cremation Treatment Burn Rate Average 25 kg/hour Feed Capacity Average 50kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature Monitor Digital Display Temperature Protection […]
we create small scale waste incinerators, the potential from 10kgs,20kgs,30kgs,50kgs,100kgs per hour. Key Features: * High speed, from 10kgs to 600kgs per hour, up to 10ton per day. * High fever, long life of incinerator. * Free or minimal installation onsite. * One year guarantee on incinerator and parts in stock.
Incinerator Model YD-150, Overview This model is middle-scale waste incineration equipment for middle waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1500Liters (1.5m3, YD-150). Primary &  Secondary combustion chambers and included mix-combustion chamber, smoke filter  chamber and Refractory Concrete chamber. Batch load on […]
 We finish this project in year 2010 to 2011 and delivery to Hochiminh port, Vietnam with 1×40’feet open top full container.
Nominal burning rate shall be 100 -140 kg/hr with 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading.Primary power source shall be electricity but capable of using diesel fuel as a supplemental fuel.The waste incinerators shall be designed for 3 Phase, 380-400 V, 50 Hz electricity supply.Should have dual combustion chambers with gas temperature achieve 1000 C for retention time at least 2 second,Have a thermal efficiency of not less than 85%.All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or  otherwise treated against atmospheric and process induced corrosion.The incinerator combustion chambers should be designed for easy maintenance of all internal parts including the  refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also  be protected against oxidation, corrosion, etc.Primary and secondary chambers preferably have rounded inside corners to avoid the formation of dead zone or cold pockets.Generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.Achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. Combustion Efficiency (CE) at least 99%.
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion chamber.  *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Basic Info. Model NO.:TS30 PLC Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Packing:Full Container Standard:30 kg per hour Origin:China Production Capacity:1000 Sets Per Year Product Description   Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator maker in China. We are local  producer and among the largest exporter of […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
i.   Circular Mild Steel / Stainless steel with minimum thickness 3mm, self-supported flange section chimney and should have suitable door/window at the base for cleaning. ii. Proper port for taking exhaust gases sample to monitor emission levels as per international standards provided with a cover to be opened and closed when needed without affecting the […]
Incinerator units shall include an integral and mechanized bottom ash removal system.Ali the measuring devices attached to the incinerator should have digital display and should have  provision of connecting to the recording system, which should include fuel meter and separate energy meter.Include designed pollution control devices such as scrubbers, filters or electrostatic precipitators to achieve emission limits.Each unit shall include a complete vertical exhaust and stack system 6-12 m above ground level with exhaust exit velocity of not less than 10 meters per second.Include clearly readable system operation panels. Spare parts:Each incinerator shall be supplied with all necessary spare parts required for two (2) years of operation (one set for each unit).Mandatory spare parts, for all the incinerators as a minimum, shall include: thermocoupletemperature gaugefire ropeburnerinduction air fandigital temperature display panel
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour  Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L Smoke Filter Chamber Optional Feed […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.com Email: hicloversales@gmail.com   Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour Feed Capacity Average 250kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1300L Internal Dimensions 120x100x110cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption […]
HICLOVER Fighting COVID-19 CE ISO