Waste Incinerator

Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

Basic Info. Usage:Industrial Place Style:Incinerator Manufacturing Level:Incinerator Media:Incinerator Fuel:Oil-fired Burning Style:Incinerator Pressure:Incinerator Water Circulation:Incinerator Gas Flow Type:Incinerator Export Markets:Global Additional Info. Trademark:CLOVER Product Description We are among the most significant waste incinerator producer and exporter of China. Pyrolytic incinerator specialized is primary waste treatment system all around the world, for Medical Waste, Animal Incineration, Pet […]
Curing Duration,need a small incinerator, they discard 100 liters of covid masks daily.batch load, direct fire,  mobile incinerator for a variety of applications including medical waste. The unit is one of the lightest in its class ,  facilitating deployment for virus outbreaks and disaster relief operations. Primarily running on diesel 1. Where can I watch a video of a real-life application? 2. The modulating under air burners ensure consistent high temperatures needed to destroy infectious waste,  whilst retaining the flue gas for sterilization. Simply load waste into the chamber, close the door and turn on the unit. 3. When approved and paid for, how many days for shipment? 4. As per the requirement we have ordered an Incinerator that can process 100kg hospital waste and as per the  end user they are only able to put 3 bags of waste which are approximately 10kg each. So we are only able to  process 30 Kg of waste instead of 100Kg. As per the hospital the chamber volume is very small and can not process 100kg hospital waste 5. Can you give me the listing of extras needed, and  installation of the TS150 PLC Incinerator and am in  need of technical assistance? 6. What are the most commonly needed repair parts?a)   Waste Auto Loading Ram Hopper  b)   Standard Tools (What the tools are there?, Please figure out) c)   Recommended spare parts (1 year) (such as burner, refactor cement, temperature probe, etc.) d)   Commissioning and Training  e)   Support wires, clamp and bracket as chimney is 33 m height              HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)   Waste Incinerator RFQ(Request for Quotation) http://www.hiclover.com/ad/rfq/   EStore for Waste Incinerators http://www.haiwos.com   2022-06-24 […]
news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html  WHO declares outbreak constitutes international public health emergency China vowed on Friday to work with the international community to uphold regional and international health security, and reiterated it has the confidence and capability to win the battle against the novel coronavirus epidemic, which has claimed 213 lives throughout the country as of Thursday. […]
Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor […]
Model A1500 (customer made model) Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Optional Part) Incinerator Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Application Scope:  Hospital& practice: Medical waste, surgical waste- Syringe, Infusion Set, Dressing, Bio-Waste, Medicine.  Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  Community & Sea Port & Station: Municipal Waste, etc.  Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn […]
Nominal burning rate shall be 100 -140 kg/hr with 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading.Primary power source shall be electricity but capable of using diesel fuel as a supplemental fuel.The waste incinerators shall be designed for 3 Phase, 380-400 V, 50 Hz electricity supply.Should have dual combustion chambers with gas temperature achieve 1000 C for retention time at least 2 second,Have a thermal efficiency of not less than 85%.All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or  otherwise treated against atmospheric and process induced corrosion.The incinerator combustion chambers should be designed for easy maintenance of all internal parts including the  refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also  be protected against oxidation, corrosion, etc.Primary and secondary chambers preferably have rounded inside corners to avoid the formation of dead zone or cold pockets.Generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.Achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. Combustion Efficiency (CE) at least 99%.
Product Description Principle of This Incinerator Gear is incineration/combustion/burn. The main body is 1 combustion chamber (at least), Refractory line or firebrick, Insulation materials and also the outer plate. Ignition component is external oil or gas burner. The burner can be sloutherhouse waste incineration lt, small 20kg incinerator, small a animal crematory equipment prices, small […]
Basic Info. Type:Incinerator Export Markets:Global Product Description Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *based on order  * High temperature, long lifetime of incinerator.  * Free or minimal installation onsite.  * High speed rate, from biology waste 2b waste burner, biomedical incinerator available for sale, biomedical waste […]
30kgs per hour(average) medical waste incinerator, design dual  combustion chambers(primary chamber and secondary chamber),  smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small  hospital medical waste treatment. Buy waste incinerator, find hiclover
Basic Info. Export Markets:Global Product Description Key Features:  * All models using Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton per day.  *based on order  * […]
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Average 20.4 Kgs/Hour Gas Consumption (m3/hour) *** Temperature […]
Common, well-proven and clean technology – both as a complete unit and in terms of its individual components. Robust and sturdy for installation in remote locations. As labor free as possible, easy to use and operated by trained but mostly unskilled operators. Require minimal pre-processing, limited need for prior sorting, crushing or shredding.Capable of handling mixed solid waste streams (non-recyclable waste with some mix of organic waste, garden waste, burnable materials such as waste wood and clothing). It can accommodate large variations in waste composition and calorific value.Operated on a daytime shift basis, five (5) days per week. Have very low unburned materials in the slag.Economical to operate and maintain and have a low and efficient fuel consumption. Have an operation manual in English.Catalogues/brochures are required. Detail Specifications for Waste Incinerators:The equipment should have a minimum life time operation often (10) years in a tropical environment.Average loading capacity of 1,000 kg/day with maximum loading capacity of 1,200 kg.
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.  b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.  solid waste incinerator for medical waste disposal china incinerators Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.  “• Heavy steel construction.The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. • Fixed hearth geometry and starved air gasification operational mode.  • Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.  • Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.  • Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints. m. incorporate an Air Pollution Control System suitable for basic emission control  n. have a thermal efficiency of not less than 85%.  o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets p. have very low levels of unburned material in the slag q. include a supplement fuel source and storage unit (e.g., diesel tank),  “r.  proposals shall include the fuel consumption at the rated capacity be CE Certified, meet relevant British, EU or American Standards, or equivalent. and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source.                 Nanjing Clover Medical Technology Co.,Ltd. Ecolead Technology(Nanjing) Co.,Ltd. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com  Email:     sales@hiclover.com  Email:     hicloversales@gmail.com       […]
Product Description Principle of This Incinerator equipment is incineration/combustion/burn. Items/Model TS100(PLC) Burn Rate 100 kg/hour Feed Capacity 200 kg Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor Yes Temperature Protection […]
Basic Info. Model NO.:waste incineration furnace Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS30(PLC) Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Specifically designed for red bag Medical wastes with high density and high moisture content.Each chamber should have at least one temperature sensorOne temperature sensor mounting point at the base of the exit flue ensuring that chamber reaches the necessary 800°C minimum. Minimum 50-100% moisture Items/Model TS100(PLC) Principle Waste Incineration Waste Treatment Animal Waste Incineration Treatment Burn Rate Average 200 kg/hour Feed Capacity Average 1000kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 17–36 Gas Consumption (m3/hour) […]
Modified burn barrels could be built using commonly available substances. They could either be pre-built independently or hauled to the site for meeting. Detailed construction programs are given in Appendix 2. Although modified burn barrels are designed to make an edge over open burning off the ground, burn boxes and unmodified burn barrels through reaching […]
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts
HICLOVER|Clover Incinerator