Waste Incinerator

Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste On-Site Incineration Solution‎ Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities,  and medical research facilities. These wastes include both infectious (“red bag”)  medical wastes as well as non-infectious, general housekeeping wastes.
1. N95 and Disposable Mask Machine   2. ES Fiber Production Line       N95 Face Mask Machine Production Line Melt blown Production Line   A.)Optional Ability: 1600mm Performance: 95-97% FOB Term Price: USD per set Cost Legitimate: 5days. Ave.60 Days ready for transport. In stock Price: USD per set     B.)Optional Capacity: […]
Product Description Items/Model YD-30 YD-50 YD-100 YD-150 Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Primary Chamber (Liters) 360 900 1200 1500 Secondary Chamber (Liters) 200 200 500 500 External Dimensions […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features:  * All versions with Dual combustion room.  *according to order  * High fever, long life of incinerator.  * Free or minimum installation on site.  * High speed, from 10kgs to 500kgs per hourto 6ton per day.  * PLC […]
Basic Info. Model NO.:used medical waste incinerator italy Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Currently , we supply different series for local customer requirements and layout updated incinerator with our top technology. The updated design characteristic of our range of incinerators create them one of the most cost effective on the […]
Incinerators must  be able to support different power sources (PV solar system ,  diesel Electric generator , local or  compound mini-scale grid).Each unit shall  include a complete vertical exhaust and stack system, including the following features: • Steel construction. Packing Details Serie No. Part Name Size(M) Weight(Kgs) 01 Incinerator Mainbody 1.8 x 1.2 x 1.7(LxWxH) […]
Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features:  Product List Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel) […]
Basic Info. Model NO.:medical waste incinerator manufacturer Export Markets:Global Product Description Key Features:  * All versions with Dual combustion chamber.  *based on sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control Plane. *based on […]
Basic Info. Export Markets:Global Product Description Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  […]
Scrubber is air pollution control devices that use liquid to remove particulate matter  or gasses from exhaust or flue gas steam. This atomized liquid (water) entrains particles  and pollutant gases in order to effectively wash them out of the gas flow.  Scrubber must be very multi-disciplinary with ability to remove solids, mist and gasses  simultaneously while also providing cooling.  Model YD-100 Picture   Burning Rate Average 100 kgs/hour Feed Capacity Average 200 kgs Primary Combustion Chamber 1200 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel […]
Stainless steel or Mild steel outer with thickness 5mm or more,  sheet should be painted with heat resistant and anti-corrosive paint.Internal surface of incinerator should be line with noncracking refractory  bricks made of ceramics or concrete to withstand the temperature of 1400 oC,  furthermore bricks must be backed by thermal insulation and have thickness in  between 220C250 mm. Model A2400 Picture Burning Rate Upto 150 kgs/hour Feed Capacity Upto 200 kgs Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.48Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel […]
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products […]
Product Description Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS50(PLC) Principle Animal Cremation Treatment Burn Rate Average 20 kg/hour Feed Capacity Average 50kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) Average […]
Basic Info. Model NO.:hospital incinerator for waste burner Export Markets:Global Product Description Items Specification Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) Main Product List Double Combustion Chamber Smoke Filter Chamber PLC Mode Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Packing:ISO Container Origin:Nanjing City China Production Capacity:1000 Sets Per Year Product Description Q: What is kind of waste can use in this equipment?  A: This equipment for pet creature, medical waste, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid waste and gas waste.  Q: Incinerator […]
Nanjing Clover Medical Technology Co.,Ltd. • Also consider provision for meeting international emission standards. Able to handle an average waste production of 100kg/day “• Minimum load capacity: 20 kg • Maximum load capacity: 40 kg • Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day) The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections The forecasted feedstock loads, and daily loading rates are generally summarized as: • Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities.   The wastes will consist of 100% biomedical wastes. • Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size. • Operation on a daytime shift basis, 5 days per week. • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion  Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion, etc.o C.E = (CO2 X 100) / (%CO2 +%CO) incinerator price incinerator for medical waste Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.” “Each unit shall include a complete vertical exhaust and stack system, including the following features: • Steel construction. The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. • Refractory lining in the lower section. • The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on the capacity of the incinerator unit.  The incinerator shell shall be made of mild steel with an adequate thickness for small units of between 3-6mm and larger units 5-10 mm depending on the construction part and painted externally with heat resistant aluminum paint suitable to withstand 250° C.  The outside surface temperature of the incinerator casing should not exceed 50° C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100 mm.  The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations. “The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle.  e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. g. include clearly readable system operation panels. h. include an operator’s manual (in English and French and Spanish). i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding. j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated. k. can accommodate large variations in waste composition and calorific value. l. allow for batch loading The control system shall include an electronic performance monitoring and logging system. The system shall be capable of monitoring and logging chamber temperatures at regular intervals (not less than once per minute, with the capacity to vary the logging frequency). The system shall include the capacity to download the performance data by USB connection.  All the measuring devices attached with the incinerator should have digital display and should have provision of connecting to the recording system, which should include fuel meter and separate energy meter. The temperature shall be determined against the inside wall of the combustion chambers. An audible and visible alarm shall be installed to warn the operator when the secondary temperature drops to below the required temperature. The primary chamber must meet or exceed the following criteria: • Multiple electric ignition fuel burners designed to use automotive diesel fuel. • Flame of the primary burner shall be oriented towards the center of the unit which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.  • The unit shall prevent leakage of the hot flue gas and any backfire.  […]
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Item Serie No. Part Name Packing List 1# Incinerator Mainbody   2# Oil Tank(Deposit)   3# Oil Tank(Daily)   4# Chimney(Vertical,High Temperature)   5# Chimney(Horizontal,High Temperature)   6# Wet Scrubber   7# Chimney(S shape)   8# Chimney(Below)   9# Chimney(Top) Hospital Incinerators for Medical […]
   Opening of the door assisted by counterweight system;   Burner capacity (under full power): 100* kg/h approximately;   Loading capacity:  150* kg/cycle approximately;   Operating temperature: 900-1000°C;Max Burning Capacity Kg/h 100*Max Loading capacity Kg/cycle 150*Advised operation Time: h 12Operating temperature in incineration chamber °C 900 – 1.000Operating temperature in postcombustion chamber °C 850 – 1.100Insulator Type Caldegun or similarRefractory Type Phlox or similar (high % Al203)   Parallelepiped shape;   Inner surface carried out with first-rate refractory material , high-temperature proof;   Combustion chamber volume: 1,2 m3 approx;   N° 1. Loading door set on the top of the burning chamber, suitable to load the waste material   N.1 Deashing door. Combustion temperature Steam exhaust pipe Exhaust pipe Ejector pipe (a) Size (b) Material (c) Air damper oil (diesel) fired150kg/hr capacity mono block fully automatic burnersburner operation is modulation controled2500 LITER FUEL STORAGE TANK (6mm mild steel made with 2 diesiel pumps,safety valve,strainer Pipe, pressure gage, check valve, control board , Level indicator. Etc )semi automated via grate and ash trolley for ash removalsemi automated ram loader for mode of waste handling with capacity 0.75m3flue gas cleaning systemstack dischargeaudio/visual alarm system
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts