Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:6.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 04 sets Oil Tank (if oil fuel): 800Liters The secondary chamber must comply with the following minimum criteria: “• Heavy steel construction small scale incinerators incinerator burner • An excess air and high temperature operational mode. • Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated. • Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times. • Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. • Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. • Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints • An electrically powered fan forced air supply, with the capacity for variation by the operator. • One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter. • A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner. Medical Waste Incineration Treatment Average 1000-1500 kg/hour Average 6000kg/feeding PLC(Programmable Logic Controller Incinerator) 4800Liter A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended. The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content. “The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment. All incinerators shall meet the following emission and operating standards: • Combustion efficiency (C.E.) shall be at least 99.0% • The combustion efficiency shall be computed as follows: • The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less than 10 metres per second vertically upwards when at full scale operation. • An emission stack sampling port shall be included immediately above the secondary chamber. ” Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator. “Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each. • The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator. The pumping system will have two pumps in parallel for redundancy. • The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line. • The unit shall be equipped with a fuel meter. “Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid) The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. All electrical connections attached with the incinerator and other machinery should be provided with suitable and necessary safety devices and be protected by steel conduits, cable trays, and supports. The manufacturer should permanently mark on the incinerator indicating: (i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture of the incinerator (iii) capacity in terms of net designed heat release in heat units per timed period (i.e., British Thermal Units per hour, mega joules per hour, kilocalories per hour). “The unit shall be supplied with a lockable operations store, that shall be initially supplied with the following consumables: • A first aid kit, suitable for addressing the hazards presented by the unit. • 5 full sets of personal protective clothing and equipment. • Operating logbooks. […]
Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed and destroyed in an appropriate manner. With years worth of experience in this sector, our medical range of incinerators are designed to cater for the economical needs of […]
single shaft shredder is firm and durable.The machine adopts knife rolls structure with dense platoon small bit, and was equipped with compulsion feed by push yard lumber and so on, it has the follows merits: slow-speed rotation, low noise, big torque, highly effective energy conservation. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com […]
Each incinerator shall be supplied with all necessary assembly/disassembly tools. Spare parts and consumables The proposed incinerator systems shall include all necessary spare parts, PPE, and consumables required for 2 years of operation. https://twitter.com/i/status/1578045332285698049 Incinerator Items/Model HICLOVER YD30(PLC) Burn Rate (Average) 30-50kg/hour(Medical Waste) 10-15kg/hour(Pet Animal Cremation) Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary […]
The new plant could help in reducing energy losses in the incineration process as well as reducing harmful emissions Wasteserv inaugurated a $12 million animal waste management in Marsa earlier now. Speaking at the inauguration of the new Wateserv EU-funded autoclave producing plant for the treatment of animal waste, Wasteserv CEO Tonio Montebello reported that […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description The incinerator lines have little scale to large scale, up to 500kgs per hour. The combustion chamber use high strength material, expensive cost but better quality than competitors. Incinerator operation system utilize PLC program control manner, give the complex manual […]
Medium Unit – to handle an average waste production of 500 kg/dayand meet the capacity as herein below indicated:Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg. Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS50(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Optional Upgrade Containerized Mobile Type Incinerator ISO 20′ Full Container Main Body Shell 6mm thickness mild steel Face Oil […]
Picture Feeding Door Location Top/Side Loading Burn Rate (up to) 200-300 kg/hour Control Mode PLC Automatic Primary Combustion Chamber 2000L(2.0M3) Primary Combustion Chamber Internal Dimensions 2000x1200x850mm Secondary Combustion Chamber 1000L(1.0m3) Feed Mode Manual/forklift/crane ***forklift/crane supply by local We are particularly interested in your range of mobile incinerators and would appreciate […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs Primary Chamber (Liters) […]
Basic Info. Model NO.:laboratory incinerators and medical / hospital in Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Is a top waste incinerator maker in China. We are local producer and among the greatest exporter of China. The capacity from 10kgs/Hr. To 500kgs/Hr. Up to 6ton daily. Presently, we provide different show for […]
Basic Info. Model NO.:medical incinerator design Export Markets:Global Product Description Technology Respond(FAQ) Q: What is kind of waste may use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. Q: Incinerator Smoke Standard A: China Government Standard: No. […]
Product Description By 17th May, 2013, company name change to be”Nanjing Clover Medical Technology Co., Ltd.” The former company”Clover Medical Limited” is as a subsidiary company. Incinerator is a incineration gear, direct fire waste from the combustion room amount capacity, the price of animal crematory, the tempreture of the stoker moving grate incinerator, the waste […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Q: What’s kind of waste may use within this equipment? A: This equipment to medical waste, pet creature, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. GB18484-2001. Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power […]
Incineradores de Residuos Médicos para Proyectos de Educación Médica y Cooperación Hospitalaria en África Introducción: El crecimiento de la educación médica en África En países como Camerún, Senegal, Mali y Guinea Ecuatorial, la expansión de las universidades médicas y hospitales universitarios desempeña un papel crucial en la formación de nuevos profesionales de la salud. Estos […]
Basic Info. Model NO.:farm animal equipment cremation creamatotium incin Export Markets:Global Product Description Key Attributes: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *based on sequence * High fever, long life of incinerator. * Free or minimal installation onsite. * High speed, from 10kgs to 500kgs per hourto 6ton daily. […]
Basic Info. Model NO.:cremation equipment for sale in china Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features: * All versions with Dual combustion room. * Stainless Steel chimney/stack, long life. *according to order * High temperature, long life of incinerator. * Free or minimal installation on site. * High burn rate, […]
Product Description The mill workshop neighborhood in liuhe Economic Development Zone, suburb of Nanjing and company office neighborhood in downtown area. Presently, incinerator line goods marketplace cover former Soviet Union area, Africa states, Asia states and Middle East area. From year 2010, we negotiated with upgraded technologies from Europe and America manufacturers and establish alliance […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: sales@hiclover.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 1.0 Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) *** Gas Consumption […]
Basic Info. Model NO.:medical waste incinerator manufacturer Export Markets:Global Product Description Key Features: * All versions with Dual combustion chamber. *based on sequence * High fever, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hourto 6ton daily. * PLC Control Plane. *based on […]