Diesel Fuel Incinerator

Basic Info.

Model NO.:medical incinerator design
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may use in this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t indicate any waste material. The animal/pet combustion speed around 2/3 of ordinary power. 

Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time to get feeding squander. Actual combustion time daily is around 16 hours. The lifetime of incinerator involving 5-10 year based on use. 

Ordinarily, we proposal little laboratory, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per individuals per day. If there are 200 sickbed in the clinic, that's mean you need one incinerator capacity around 400kgs every day, switch to power per hour is around 30-40 kgs per hour. According the performance time every day, waste material, funding, growth, etc, you may use capacity from 30-50 kgs per hour incinerator.  *The best way to calculate Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We supply all files and incinerators easy to setup and functionality. Client can send individuals visit our factory to find out installation and operation. Diesel oil fired medical waste incenerator, dual chamber incinerator, ecological incinerator, encenerator, farm incinerator, Ordinarily, We do not send engineer to neighborhood site if not ask. The dispatch price is additional based on order. 

Q: Combustion Temperature  A: The very first combustion chamber: 800-1000 centi level.  The next combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control mode is common control instance. PLC mode based on order and model. 

One individual can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, and understand threat of medical waste to safeguard worker self with necessary protection element. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm