Waste Incinerator

Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

Basic Info. Model NO.:pet cremation incinerator cost Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. A Model animal crematory burning rate from 20-400kgs a hour. Heavy duty combustion room and suit for large animal cremation.  In post combustion chamber. Virtually smoke and odor free.  Smoke Filter Chamber with filter brick, Virtually smoke and […]
Thermocouples (S type) Thermocouples Tube(Corundum ) PLC Recording Function 5mm Steel shell Window on feed door     Incinerator Items/Model HICLOVER YD500(PLC) HICLOVER YD600(PLC) Burn Rate (Average) 500-600 kg/hour 600-800 kg/hour Feed Capacity(Average) 800kg/feeding 11000kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 4000L(4.0M3) 5500L(5.5M3) Internal Dimensions 257x147x108cm 300x147x125cm Secondary Chamber 1500L 1500L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V […]
Stainless steel or Mild steel outer with thickness 5mm or more,  sheet should be painted with heat resistant and anti-corrosive paint.Internal surface of incinerator should be line with noncracking refractory  bricks made of ceramics or concrete to withstand the temperature of 1400 oC,  furthermore bricks must be backed by thermal insulation and have thickness in  between 220C250 mm. Model A2400 Picture Burning Rate Upto 150 kgs/hour Feed Capacity Upto 200 kgs Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.48Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel […]
Pre-assembled, containerized type Incinerator Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor […]
Item Specification Model YD-10 Main Product List Combustion Chamber Control Case Stack: 3.0Meters Oil burner: 02 units Oil Tank (if oil fuel):50Liters Equipment Technical Specifications Model YD-10 Picture Feed Capacity Average 20 kgs per feed Burning Rate Average 15 kgs per hour Burning Time per Feed 2 hours Voltage 220V Power 0.5Kw Fuel Diesel oil […]
Product Description Application Scope  1. As above two reason although not only above, we still utilize incinerators.  How you are able to discover reasonable incinerator for your regional website?  Incinerator isn’t a cheap equipment, normally the small scale model's price around $5, 000usd per unit and big scale model's price more than $50, 000usd per […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Product Description Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs Picture   Primary Chamber (Liters) 200 […]
Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.   The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Waste Incineration Treatment Diesel Oil type Model TS150 Main Parts List as below: Primary combustion chamber Secondary combustion chamber smoke filter chamber incinerator PLC control case chimney, 10meters, stainless steel Italy Oil fule burner oil tank 300liters with full spare parts: oil burner, air blower, temperature thermocouple
This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil burner,  batch load incineration equipment. Waste feed chamber is 2000Liters (2.0m3, TS300 PLC).  Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the  bottom of chamber. Incinerator PLC panel control suit for […]
Question: Brick and refractories to withstand 1700°C (3092°F) Our std. high density castable refractory material is rated for 3000°F (1649°C).  There is 3100°F material available but is considerably more expensive and labour intensive to work with. The point is why?  The incinerator will never exceed 2200°F (actually 2000°F), so what is the value?    TRHA Response: […]
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 500kgs/Hr., up […]
CAPACITY : Burner 150 kg/hr. Quantity: Two [2] with complete accessories. kinds of wastes being used: GENERAL WASTE The  machines will be certified for operation from PME after passing site investigations. The technical details we all care about are: –          Ability (burning capability of waste per hour). 150kg/hour. –          Assemble materials, 5mm High quality mild […]
Chairman of the South West Regional Health Authority (SWRHA) Dr Lackram Bodoe said a back-up of medical waste at the San Fernando General Hospital had to do with a delay in payment to a contractor Rather than the malfunctioning of This incinerator. Responding to complaints about the risks posed by the gathered medical waste, which […]
Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural […]
1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i.   Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. Chamber be designed with capacity to load 100kg medical waste with volume at least 1.2m3 or more, chamber must have separate door for loading of waste and for removal of ash using manual ash removing tool. ii. Pyrolytic burning mechanism with burning temperature not below than 900 oC. iii. Blower Centrifugal fan (according to manufacturer design) will be provided to inject air for burning waste and gases in primary combustion chamber furthermore air  regulation and distribution will be automatic and electronically controlled. iv.  Chamber should have electrically operated natural gas burner. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   […]
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts