Waste Incinerator

Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

Waste Incinerator Capacity average 30-50 kgs per hour   Model YD-30C Main Product List   Primary Combustion Chamber     Secondary Combustion Chamber     Mix-Combustion Chamber     Smoke Filter Chamber     Incinerator Control Case (PLC Auto Type)     Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)     Italy oil burner: 02 sets     Oil Tank: 200Liters     […]
Model CA100 Waste Treatment Waste Incineration Treatment Feed Capacity Average 100 kgs per feed Burning Rate Average 100 kgs per hour Burning Time per Feed Average 1 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 0.7Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption (Oil) Average […]
Medical Waste Incineration Market in Nigeria  Nigeria, the largest economy in Africa with over 220 million people, has a rapidly expanding healthcare system comprising: Over 30 federal teaching hospitals Hundreds of state and specialist hospitals Thousands of private clinics and diagnostic centers The volume of infectious medical waste—such as sharps, pathological waste, and contaminated materials—has […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm […]
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components. b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions. d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Product Description Key Attributes:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per […]
This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil/gas burner.  Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary  combustion chambers and included mix-combustion chamber. Waste load on the  bottom of chamber. Incinerator panel control suit for local operation. Model YD-50 with […]
We are ready to send new Waste incinerator for Ethiopia. We arrange all shipping to Djibouti port. This shipping delivery with CIQ(CHINA ENTRY-EXIT INSPECTION AND QUARANTINE), Chamberized Commercial Invoice, CO, etc document/certification. See video show this web link: https://vimeo.com/235864206 Model YD300  Burning Rate Average 300 kgs/hour Feed Capacity Average 500 kgs Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:Clover Medical Product Description Key Attributes:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *based on sequence * High temperature, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model YD-10C YD-20C YD-30C YD-50C Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr. Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs Primary Chamber (Liters) […]
Model YD-30 Mobile Type Picture   Burning Rate Average 30 kgs/hour Feed Capacity Average 60 kgs/feeding Chamber Main Body Stainless Steel Mobile Function With Wheel and Brake Primary Combustion Chamber 280 Liters Secondary Combustion Chamber 150 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 1.5 Kw Fuel Type Diesel Oil Burner Italy […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Key Attributes:  * All models with Dual combustion room. *based on order  * Stainless Steel chimney/stack, long lifetime. *based on order  * High temperature, long lifetime of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up […]
Items/Model TS50 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 100kg/feeding Control Mode Electric Controller Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Wet Scrubber System, 3 section type/guidelines on waste management Feed Mode Manual Voltage 380V Power 10 Kw Oil Consumption (kg/hour) *** Gas Consumption (m3/hour) Average […]
Items/Model TS50(PLC) Principle Animal Cremation Treatment Burn Rate Average 25 kg/hour Feed Capacity Average 50kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature Monitor Digital Display Temperature Protection […]
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Items Side Loading Door Top Loading Door Reference Cost Cheap High cost Manufacture Tech. Easy A litter difficult Safty safe safer Incinerator Shape L/ I L Loading manual big door can be by Forklift Land occupation small big Ash door same with feeding door or […]
Items/Model TS1000 Picture   Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil […]
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Main Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:10.0Meters *(Update to […]
1 off combustion air supply fan and distribution systemHigh capacity secondary combustion chamber 2.0 @ >1050oC1 off diesel-fired afterburner C temperature controlledControl panel C automatic operationTemperature indication primary and secondary chambers 0-1200oCA secondary afterburning emission control chamber.A discharge chimney.Control  panel-  time  and  temperature  dedicated  control  system,  housed  within  an incinerator mounted control cabinet Unit to be capable of burning high calorific value solid, liquid and sludge waste and shall be as modified version of the Surefire incinerator by Matthews environmental solutions  or as approvedSupply and install and or fabricate as wet scrubber Model – SF50/1 wet scrubber to be positioned horizontally on the chimney and manufactured from mild steel horizontal section painted with enamel paint finish, refractory lined inner section with cold face insulation of calcium silicate all to achieve a thickness of 100mm and provide internal diameter of 420mm, stainless steel spray nozzle along the refractory lining, stainless steel tank of holding capacity 250litres complete with stainless steel float valve, Hot water pump model Daylif DB 2/30 for circulation of hot water in the scrubber and galvanised piping complete with valves, strainers and water flow bypass.Automatically controlled burn and cool down period.This chamber should be equipped with burners that use low sulphur fuel.1 Diesel fired Ignition Burner1 set combustion air distribution pipe work 1 Observation port with protective glass and 1 thermocouple1 Flue gas outlet to secondary combustion chamber- Should be lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable. Health Care Waste management (HCWM) and would need to implement a semi industrial incinerator Feed chamber/charging door.Control panel C automatic operationTemperature indication primary and secondary chambers 0-1200oCHorizontal solid hearth, refractory lined primary combustion chamber 850mm diameter x 2000mm longFull sized bulk load/ash removal door2 off diesel-fired ignition burner C temperature controlled-Perforated  and  filter  panels  for  fly  ash  and  smoke  removal-Electrical control panel with visual display of temperatures and plant cycles-Electrically  operated   rising   loading   door   for   hand   charging-Ash  door  diameter  1460mm,loading  door  670mm  x  600mm-Other        necessary        accessories        and        testing        fuel-Installation and overhead costs included
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts
HICLOVER|Clover Incinerator