Waste Incinerator

Containerized Mobile Waste Incinerator| Incinerator|Medical Waste Incinerator|Environmental Incinerator|Pet Animal Incinerator|Medical Incinerator|Incinerator Manufacturer|China Incinerator|Medical Incinerators|www.ctwct.com|Tel: +8613813931455(WhatsApp)

hazardous waste disposal incinerator http://www.military-camps-incinerator.com/  Incinerator Items/Model HICLOVER TS100(PLC) HICLOVER TS150(PLC) Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour Feed Capacity(Average) 200kg/feeding 300kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) 1500Liters(1.5m3) Internal Dimensions 120x100x100cm 1500x1000x1000mm Secondary Chamber 600L 750Liters(1.0m3) Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.7Kw […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Program Scope:  1. Incinerator is a incineration equipment, direct fire squander by gasoline fuel or oi gas. As distinct circumscription, incinerator can be named many words as under:  Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant.  Waste substance: Municipal waste incinerator, medical waste […]
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description How you are able to find reasonable incinerator for your regional website?  Incinerator isn’t a cheap equipment, normally the little scale version 's cost around $5, 000usd per unit and large scale version 's price greater than $50, 000usd each […]
Key Word: small incinerators medical waste incinerator pet animal cremation incinerator incinerator manufacturers     Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:   Treatment capacity: small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal […]
Nanjing Clover Medical Technology Co.,Ltd. • Also consider provision for meeting international emission standards. Able to handle an average waste production of 100kg/day “• Minimum load capacity: 20 kg • Maximum load capacity: 40 kg • Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day) The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections The forecasted feedstock loads, and daily loading rates are generally summarized as: • Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities.   The wastes will consist of 100% biomedical wastes. • Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size. • Operation on a daytime shift basis, 5 days per week. • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion  Principle Medical Waste Incineration Treatment Burn Rate Average 1000-1500 kg/hour Feed Capacity Average 6000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter  Internal Dimensions 400*120*100 cm The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion, etc.o C.E = (CO2 X 100) / (%CO2 +%CO) incinerator price incinerator for medical waste Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.” “Each unit shall include a complete vertical exhaust and stack system, including the following features: • Steel construction. The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers. • Refractory lining in the lower section. • The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on the capacity of the incinerator unit.  The incinerator shell shall be made of mild steel with an adequate thickness for small units of between 3-6mm and larger units 5-10 mm depending on the construction part and painted externally with heat resistant aluminum paint suitable to withstand 250° C.  The outside surface temperature of the incinerator casing should not exceed 50° C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100 mm.  The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations. “The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle.  e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. g. include clearly readable system operation panels. h. include an operator’s manual (in English and French and Spanish). i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding. j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated. k. can accommodate large variations in waste composition and calorific value. l. allow for batch loading The control system shall include an electronic performance monitoring and logging system. The system shall be capable of monitoring and logging chamber temperatures at regular intervals (not less than once per minute, with the capacity to vary the logging frequency). The system shall include the capacity to download the performance data by USB connection.  All the measuring devices attached with the incinerator should have digital display and should have provision of connecting to the recording system, which should include fuel meter and separate energy meter. The temperature shall be determined against the inside wall of the combustion chambers. An audible and visible alarm shall be installed to warn the operator when the secondary temperature drops to below the required temperature. The primary chamber must meet or exceed the following criteria: • Multiple electric ignition fuel burners designed to use automotive diesel fuel. • Flame of the primary burner shall be oriented towards the center of the unit which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.  • The unit shall prevent leakage of the hot flue gas and any backfire.  […]
Mobile Small Scale Medical Waste Incinerator with Trolley(E-Power) or Wheel Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel […]
Product Description Items Specification YDC Model YD-10C / YD-20C / YD-30C / YD-50C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator Common Control Case Stainless Steel Chimney Italy oil/gas burner: 02 units Oil Tank (if oil fuel)
TS100 incinerator exert the advantages and discard the disadvantages of  the same kind of equipment at domestic and abroad. It is an unique and  international advanced incineration equipment. The equipment is small size,  high efficiency, reasonable process, leading technologies and a high  harmless degree, ideal garbage treatment equipment for farm, hospital,  laboratory, hotel, station, etc. […]
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Key Attributes:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High fever, long life of incinerator.  * Free or minimal installation onsite.  * High speed, from 10kgs to 500kgs per hour, up to 6ton daily.  *based on […]
Items/Model TS50(PLC) Principle Animal Cremation Treatment Burn Rate Average 25 kg/hour Feed Capacity Average 50kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 12.1–24 Gas Consumption (m3/hour) 9.9–26.1 Temperature Monitor Digital Display Temperature Protection […]
we create small scale waste incinerators, the potential from 10kgs,20kgs,30kgs,50kgs,100kgs per hour. Key Features: * High speed, from 10kgs to 600kgs per hour, up to 10ton per day. * High fever, long life of incinerator. * Free or minimal installation onsite. * One year guarantee on incinerator and parts in stock.
Incinerator Model YD-150, Overview This model is middle-scale waste incineration equipment for middle waste output.  Construction is dual/double combustion chamber with 02 units oil burner, batch load  incineration equipment. Waste feed chamber is 1500Liters (1.5m3, YD-150). Primary &  Secondary combustion chambers and included mix-combustion chamber, smoke filter  chamber and Refractory Concrete chamber. Batch load on […]
 We finish this project in year 2010 to 2011 and delivery to Hochiminh port, Vietnam with 1×40’feet open top full container.
Nominal burning rate shall be 100 -140 kg/hr with 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading.Primary power source shall be electricity but capable of using diesel fuel as a supplemental fuel.The waste incinerators shall be designed for 3 Phase, 380-400 V, 50 Hz electricity supply.Should have dual combustion chambers with gas temperature achieve 1000 C for retention time at least 2 second,Have a thermal efficiency of not less than 85%.All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or  otherwise treated against atmospheric and process induced corrosion.The incinerator combustion chambers should be designed for easy maintenance of all internal parts including the  refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also  be protected against oxidation, corrosion, etc.Primary and secondary chambers preferably have rounded inside corners to avoid the formation of dead zone or cold pockets.Generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.Achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. Combustion Efficiency (CE) at least 99%.
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Key Features:  * All models with Dual combustion chamber.  *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High speed, from 10kgs to 500kgs per hourto 6ton daily.  * PLC Control […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
Basic Info. Model NO.:TS30 PLC Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Packing:Full Container Standard:30 kg per hour Origin:China Production Capacity:1000 Sets Per Year Product Description   Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator maker in China. We are local  producer and among the largest exporter of […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
i.   Circular Mild Steel / Stainless steel with minimum thickness 3mm, self-supported flange section chimney and should have suitable door/window at the base for cleaning. ii. Proper port for taking exhaust gases sample to monitor emission levels as per international standards provided with a cover to be opened and closed when needed without affecting the […]
Incinerator units shall include an integral and mechanized bottom ash removal system.Ali the measuring devices attached to the incinerator should have digital display and should have  provision of connecting to the recording system, which should include fuel meter and separate energy meter.Include designed pollution control devices such as scrubbers, filters or electrostatic precipitators to achieve emission limits.Each unit shall include a complete vertical exhaust and stack system 6-12 m above ground level with exhaust exit velocity of not less than 10 meters per second.Include clearly readable system operation panels. Spare parts:Each incinerator shall be supplied with all necessary spare parts required for two (2) years of operation (one set for each unit).Mandatory spare parts, for all the incinerators as a minimum, shall include: thermocoupletemperature gaugefire ropeburnerinduction air fandigital temperature display panel
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts
HICLOVER|Clover Incinerator