Chairman of the South West Regional Health Authority (SWRHA) Dr Lackram Bodoe said a back-up of medical waste at the San Fernando General Hospital had to do with a delay in payment to a contractor Rather than the malfunctioning of This incinerator. Responding to complaints about the risks posed by the gathered medical waste, which […]
Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural […]
1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i. Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. Chamber be designed with capacity to load 100kg medical waste with volume at least 1.2m3 or more, chamber must have separate door for loading of waste and for removal of ash using manual ash removing tool. ii. Pyrolytic burning mechanism with burning temperature not below than 900 oC. iii. Blower Centrifugal fan (according to manufacturer design) will be provided to inject air for burning waste and gases in primary combustion chamber furthermore air regulation and distribution will be automatic and electronically controlled. iv. Chamber should have electrically operated natural gas burner. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com […]
Basic Info. Model NO.:waste incinerators equipment manufacturers Export Markets:Global Product Description Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *based on order * High fever, long life of incinerator. * Free or minimal installation onsite. * High speed, from 10kgs to 500kgs per hour, up to 6ton daily. […]
Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower Incinerator Items/Model HICLOVER TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Burner Type Italy Brand Oil […]
Basic Info. Export Markets:Global Additional Info. Trademark:CLOVER Product Description Q: What’s kind of waste may use within this gear? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid gas and waste waste. GB18484-2001. Q: Treatment capacity A: Average Ability calculated by medical waste(lower calorific power […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: sales@hiclover.comEmail: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. […]
Basic Info. Model NO.:30kg/hr medical incinerators Export Markets:Global Product Description Technology Respond(FAQ) Q: What is kind of waste can use in this equipment? A: This equipment for medical waste, pet creature, Municipal waste, live waste. Prohibit any explosive and radiation substance, liquid waste and gas waste. Q: Incinerator Smoke Standard A: China Government Standard: No. […]
Containerized Mobile Incinerator͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ ͏ […]
Basic Info. Model NO.:Programmable Logic Controller Incinerator Usage:Industrial Place Style:Vertical Manufacturing Level:Incinerator Media:Organic Heat Transfer Material Fuel:Oil-fired Burning Style:Grate Furnace Pressure:Incinerator Water Circulation:Incinerator Gas Flow Type:Incinerator Export Markets:Global Additional Info. Trademark:CLOVER Packing:Full ISO Container Origin:Nanjing China Production Capacity:1000 Sets Per Year Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) […]
Clover supply optional dust wet scrubber system for waste incinerators. the main parts included wet cooling spray scrubber, wet dust filter and fog&waste separator. This system is valid for mid-large scale waste incinerator, model YD150,YD200,YD300,YD500,YD600. for small scale waste incinerator, supply dry scrubber(filter) chamber.
Medical Waste Incinerator Manual load twin chamber incinerator for medical waste to burn 50kg/hr on continuous operation, with Primary temperature in the region of 800degC minimal and 1200degC or longer at the Secondary chamber, complete with charging doorway, Ash doorway, Air and view vents, auxiliary air system with adjustable dampers, burners and burner control system […]
Basic Info. Model NO.:medical waste incinerator Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator Maker in China. Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High fever, long lifetime of incinerator. * Free or minimum installation on […]
Small Waste Incinerator, 10kgs per hour capacity, PLC control
Product Description Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator could be termed many words as below: Treatment ability: Small scale incinerator, big scale incinerator and incineration pant. Waste substance: Municipal waste incinerator, medical waste created in ghana, medical waste in azerbaijan, medical waste in […]
Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters Stainless Steel Italy gas burner: 02 sets Oil Tank (if oil fuel): […]
Basic Info. Export Markets:Global Product Description Key Attributes: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *based on order * High temperature, long life of incinerator. * Free or minimum installation onsite. * High speed, from 10kgs to 500kgs per hour, up to 6ton daily. *based on order New Design […]
PLC( Programmable Logic Controller), Intelligent and Automatic operation. Set combuston time according to different waste material and incinerator stop combustion itself. Set temperature protection parameter, if the temperature overheat, incinerator stop combustion itself.
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: sales@hiclover.comEmail: hicloversales@gmail.com Items/Model TS100 Burn Rate Average 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor […]
75 Kg/hour waste materials of biological Items/Model TS75(PLC) Principle Waste Incineration Waste Treatment Medical Waste Incineration Treatment Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) […]