Clover Medical Limited

Waste Incinerator Made in China

        Call Us on +8625-84610201

Mail: cloverincinerator@Gmail.com

              
   
  
       
   汉语   
  English   
   Pусский  

 Nanjing Clover Medical Technology Co.,Ltd.
 Tel: +86-25-8461 0201
 Fax: +86-25-8461 0406
 Website:
www.clover-incinerator.com
 Email:
cloverincinerator@Gmail.com
 Email:
sales@clover-incinerator.com
 Service Skype ID: clover-incinerator

 

Home

Incinerator Models

Medical Incinerators

MSW Incinerators

Small Incinerators

Pet Crematory

Contact Us


 Medical Incinerator

Model YD-30 Incinerator

Model YD-50 Incinerator

Model YD-100 Incinerator

Model YD-200 Incinerator

Model YD-150 Incinerator

Model YD-300 Incinerator

Model YD-500 Incinerator

Model YD-600 Incinerator

 Large MSW Incinerator

Model MSW1000 Incinerator

Model MSW2000 Incinerator

Model MSW3000 Incinerator

Model MSW4000 Incinerator

Model MSW5500 Incinerator

 Small Incinerator

Model YD-10 Incinerator New

Model YD-15C Incinerator

Model YD-20C Incinerator

Model YD-30C Incinerator

Model YD-50C Incinerator New

 Pet Crematory

Animal Crematory A360

Animal Crematory A900

Animal Crematory A1500

Animal Crematory A2400

Animal Crematory A4000

Model SYC-50 Incinerator

Model SYC-100 Incinerator

 Economical Incinerator

Model YZ-20 Incinerator

Model YZ-50 Incinerator

Model YZ-100 Incinerator

Model YZ-150 Incinerator

 

 

 

 

Municipal Solid Waste Incinerator

     

 

Equipment Technical Specifications

Model

MSW1000 MSW2000 MSW3000 MSW4000 MSW5500

Feed Capacity (kgs/feed)

200-400 400-800 600-1200 1000-2000 1200-2400

Burning Rate (Kgs/Hour)

100 150 200 350 450

Voltage

220V/380V

Power (Kw)

0.7 1.03 1.48 2.24 2.6

Fuel

Natural Gas or Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil, Kgs/Hour)

8.0-20.0 14.0-30.0 14.0-34.0 22.0-40.0 30.0-50.0

Fuel consumption (Gas, M3/Hour)

10.0-20.0 13.0-35.0 13.0-38.0 20.0-45.0 28.0-60.0

Waste combustion chamber (Liters)

1000 2000 3000 4000 5500

Post Combustion Chamber (Liters)

300 500 1200 1500 1500

Chimney

5.0M 10.0M 10.0M 14.0M 14.0m

Gross Weight

4500Kgs 7600Kgs 9500Kgs 13000Kgs 16500kgs

Chamber Material

Firebrick ,Refractory Concrete

Max. Heat Value (Kcal/Hr.)

200,000 300,000 340,000 400,000 500,000

Operation Technical Specifications

Solid Chamber temperature

800 0C -1000 0C

Gas Chamber temperature

1000 0C -1200 0C

Chamber Anti-Rate

14500C

Residency time

2.0 Sec.

Burning efficiency

90-95%

 

 

 

 

 

 

 

  
    www.clover-incinerator.com     