WWW.HICLOVER.COM

Large incinerators – INDUSTRIAL INCINERATORS

Large incinerators – INDUSTRIAL INCINERATORS  2.) Size requirement for the incinerators is 750 — 850 kg capacity 3.) The bum rate should be 80 LL 100 kg/ hour. 4) The primary chamber shouId have an operating temperature of 900 -1200 degree C. 5) The incinerator should hate a high temperature secondary chamber and 2 second gas retention time at 850- 1150 degree C so that it is suitable for high risk materials. 6). The incinerator should have temperature monitoring and thermostat control for ease of operation and assurance of bum temperature to confirm correct operation. 7). The incinerator should be capable of burning any of the hazardous wastes listed in the subsequent section. 8) The incinerator should be capable of burning diesel oil and should include a larger fuel tank (10-500 litres) and generator (3 –40 kV) set that can be carried on the trailer with the incinerator so that the unit requires no external electrical power supply. 9.) The incinerator should be trailer mounted so that it is a po Hazardous Waste to be Incinerated Hazardous solid chemical: Different types of combustible solids, used textiles, grease, and toner cartridges, chemicals for water purification and photographic consumables and plastic material, empty plastic/metal cans that still contain remnant hazardous material, oil absorbent. Hazardous liquid chemical: Mainly different types. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-less Solvents, Synthetic Liquid for Break Systems, Aircraft De-icing Liquid, Hydraulic and Compressor oil, Freon, used in some older refrigeration units, Insecticide liquid/spray, air refresh spray and other similar chemicals….

Large incinerators – INDUSTRIAL INCINERATORS

Large incinerators – INDUSTRIAL INCINERATORS  2.) Size requirement for the incinerators is 750 — 850 kg capacity 3.) The bum rate should be 80 LL 100 kg/ hour. 4) The primary chamber shouId have an operating temperature of 900 -1200 degree C. 5) The incinerator should hate a high temperature secondary chamber and 2 second gas retention time at 850- 1150 degree C so that it is suitable for high risk materials. 6). The incinerator should have temperature monitoring and thermostat control for ease of operation and assurance of bum temperature to confirm correct operation. 7). The incinerator should be capable of burning any of the hazardous wastes listed in the subsequent section. 8) The incinerator should be capable of burning diesel oil and should include a larger fuel tank (10-500 litres) and generator (3 –40 kV) set that can be carried on the trailer with the incinerator so that the unit requires no external electrical power supply. 9.) The incinerator should be trailer mounted so that it is a po Hazardous Waste to be Incinerated Hazardous solid chemical: Different types of combustible solids, used textiles, grease, and toner cartridges, chemicals for water purification and photographic consumables and plastic material, empty plastic/metal cans that still contain remnant hazardous material, oil absorbent. Hazardous liquid chemical: Mainly different types. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-less Solvents, Synthetic Liquid for Break Systems, Aircraft De-icing Liquid, Hydraulic and Compressor oil, Freon, used in some older refrigeration units, Insecticide liquid/spray, air refresh spray and other similar chemicals….

SPECIFICATIONS OF THE JKUAT INCINERATOR

SPECIFICATIONS OF THE JKUAT INCINERATOR It should  be  a three chambered incinerator  The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.

SPECIFICATIONS OF THE JKUAT INCINERATOR

SPECIFICATIONS OF THE JKUAT INCINERATOR It should  be  a three chambered incinerator  The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.

250 – 300 kg/hr burning capacity incinerator

250 – 300 kg/hr burning capacity incinerator Type of incinerator : Pyrolitic – hot medical waste disposing machine Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: continuous loading, Top Loading Capacity/Burn rate per hour: 250 -300 kg/hr  Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber: Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      …

250 – 300 kg/hr burning capacity incinerator

250 – 300 kg/hr burning capacity incinerator Type of incinerator : Pyrolitic – hot medical waste disposing machine Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: continuous loading, Top Loading Capacity/Burn rate per hour: 250 -300 kg/hr  Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber: Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                      …

Required Specifications Incinerators

Required Specifications Incinerators Should have required certification standards from approved certification regulatory body.  Incinerator should be able to burn hazardous and non-hazardous waste at a minimum temperatures of 850’C-1100’c Must have two chambers that’s primary chamber catering for destruction burning at 850’c and secondary chamber for destruction of gaseous waste burning at 1100’c.  Incinerators must meet medical waste disposal provisions mechanism in accordance with NEMA regulations and requirements.  Incinerators must all meet the ambient air pollutant guidelines.  Incinerator should meet the sitting ground ambient requirements as per site.  Housing shed for incinerator should meet minimum standards to allow free movement of incinerator operators and waste storage area Incinerators chimney must be heavy duty, durable and heat resistant to burst during combustion.  Incinerator door must be heavyduty, durable and tight to avoid smoke in let during combustion. Incinerator must have bulk load capacity of upto 300kgs with a minimum destruction capacity of up 100kgs per hour Waste shed housing the incinerator with enough working space and waste storage area Must have an ash pit with a capacity of up 10,000 ltrs. Must meet all occupation health safety and environment requirements and hazards.  Required Specifications Incinerators Should have required certification standards from approved certification regulatory body.  Incinerator should be able to burn hazardous and non-hazardous waste at a minimum temperatures of 850’C-1100’c Must have two chambers that’s primary chamber catering for destruction burning at 850’c and secondary chamber for destruction of gaseous waste burning at 1100’c.  Incinerators must meet medical waste disposal provisions mechanism in accordance with NEMA regulations and requirements.  Incinerators must all meet the ambient air pollutant guidelines.  Incinerator should meet the sitting ground ambient requirements as per site.  Housing shed for incinerator should meet minimum standards to allow free movement of incinerator operators and waste storage area Incinerators chimney must be heavy duty, durable and heat resistant to burst during combustion.  Incinerator door must be heavyduty, durable and tight to avoid smoke in let during combustion….

Required Specifications Incinerators

Required Specifications Incinerators Should have required certification standards from approved certification regulatory body.  Incinerator should be able to burn hazardous and non-hazardous waste at a minimum temperatures of 850’C-1100’c Must have two chambers that’s primary chamber catering for destruction burning at 850’c and secondary chamber for destruction of gaseous waste burning at 1100’c.  Incinerators must meet medical waste disposal provisions mechanism in accordance with NEMA regulations and requirements.  Incinerators must all meet the ambient air pollutant guidelines.  Incinerator should meet the sitting ground ambient requirements as per site.  Housing shed for incinerator should meet minimum standards to allow free movement of incinerator operators and waste storage area Incinerators chimney must be heavy duty, durable and heat resistant to burst during combustion.  Incinerator door must be heavyduty, durable and tight to avoid smoke in let during combustion. Incinerator must have bulk load capacity of upto 300kgs with a minimum destruction capacity of up 100kgs per hour Waste shed housing the incinerator with enough working space and waste storage area Must have an ash pit with a capacity of up 10,000 ltrs. Must meet all occupation health safety and environment requirements and hazards.  Required Specifications Incinerators Should have required certification standards from approved certification regulatory body.  Incinerator should be able to burn hazardous and non-hazardous waste at a minimum temperatures of 850’C-1100’c Must have two chambers that’s primary chamber catering for destruction burning at 850’c and secondary chamber for destruction of gaseous waste burning at 1100’c.  Incinerators must meet medical waste disposal provisions mechanism in accordance with NEMA regulations and requirements.  Incinerators must all meet the ambient air pollutant guidelines.  Incinerator should meet the sitting ground ambient requirements as per site.  Housing shed for incinerator should meet minimum standards to allow free movement of incinerator operators and waste storage area Incinerators chimney must be heavy duty, durable and heat resistant to burst during combustion.  Incinerator door must be heavyduty, durable and tight to avoid smoke in let during combustion….