Q: What is kind of waste may use in this equipment?  A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste.  GB18484-2001. 

Q: Treatment capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not mean any waste material. The animal/pet combustion rate around 2/3 of ordinary capacity. 

Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time and time to get feeding waste. Actual combustion time per day is about 16 hours. The life of incinerator involving 5-10 year according to use. 

Generally, we proposition small laboratory, small clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output capacity around 2kgs per individuals every day. If there are 200 sickbed at the hospital, that's imply you need one incinerator capability around 400kgs every day, change to capacity per hour is around 30-40 kgs per hour. Incinerators 150 kg per hour, incinerators 300 kg per hour, big incinerator, medical incinerator design, health incinerator Italy, Based the performance time every day, waste material, funding, development, etc, you may use capacity from 30-50 kgs each hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all documents and incinerators easy to setup and operation. Client can send individuals come to our factory to learn operation and installation. Generally, we don’t send engineer to local site if not ask. The dispatch price is additional according to order.  The next combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control manner is common control instance. PLC mode according to order and model. 

Q: Operation and maintenance costs  A: Operation price according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD annually maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know threat of medical waste to protect worker self with essential protection component. 

Q: The Residency period in secondary combustion chamber  A: 02 sec.

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm