Category: Clover News

The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion The incinerator combustion chamber(s) […]
Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves,  protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   Incinerator Items/Model HICLOVER YD300(PLC) HICLOVER YD500(PLC) Burn Rate (Average) 300-500 kg/hour 500-600 kg/hour Feed Capacity(Average) 480kg/feeding 800kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 2400L(2.4M3) 4000L(4.0M3) Internal Dimensions 220x110x100cm 257x147x108cm Secondary Chamber 1200L 1500L Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V   Burning temperature First combustion chamber: 800- 900 ℃ ; Secondary combustion chamber:2000℃ Flue gas residence time≥1s […]
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS100 Burn Rate Average 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor […]
Incinerator Model TS200 PLC, Overview This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil burner,  batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS200 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator […]
  Model TS10 Incinerator with wet scrubber (Spray Tower) and Defogging Tower Incinerator Items/Model HICLOVER TS10(PLC)   Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Burner Type Italy Brand Oil […]
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour  Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L Smoke Filter Chamber Optional Feed […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
waste incinerator combustion chamber firebrick WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm […]
Specifically designed for red bag Medical wastes with high density and high moisture content.Each chamber should have at least one temperature sensorOne temperature sensor mounting point at the base of the exit flue ensuring that chamber reaches the necessary 800°C minimum. Minimum 50-100% moisture Items/Model TS100(PLC) Principle Waste Incineration Waste Treatment Animal Waste Incineration Treatment Burn Rate Average 200 kg/hour Feed Capacity Average 1000kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 17–36 Gas Consumption (m3/hour) […]
Items/Model TS50A (PLC) Principle Waste Incineration Waste Treatment Medical Waste Incineration Treatment Burn Rate Average 50A kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 700L Internal Dimensions 110x80x80cm Secondary Chamber 500L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 50Hz Power 0.77Kw Oil Consumption (kg/hour) 12.1–23.9 Gas Consumption (m3/hour) 9.9–26.1 Temperature Monitor Digital […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.comEmail: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd.
Items/Model TS1000 Picture   Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil […]
a) lncineration capacity: 75 kg/hr.– up to 100kgs/hour b) Number of combustion chamber: Two (02)—yes c) Operating temperature in primary chamber: 850±50 °C— 800°C-1000°C d) Operating temperature in secondary chamber: 1200±50 °C— 1000°C-1300°C e) Burner type: Pressure jet diesel fired—yes f) Power system: Three phase, 50 Hz, 380 – 440  VAC—yes g) MOC: Vendor to […]
Incinerator Equipment Performance Requirements The principal activities of the Contract are the supply, install, commissioning and operations training. The required standards for the Contract activities are set out in the following Scope of Works below. The required minimum performance criteria for the incinerator to be provided by the bidder(s) is set out in this section. […]
Items/Model TS1000 Picture   Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil […]
This model is small-scale animal cremation equipment for small pets and animals.  Construction is dual/double combustion chamber with 02 units oil/gas burner,  batch load incineration equipment. Animal feed chamber is 360Liters (Model: A360).  Primary & Secondary combustion chambers and included mix-combustion chamber,  smoke filter chamber with firebrick and Refractory Concrete chamber(as quotation detail).  Batch load […]
Nominal burning rate shall be 100 -140 kg/hr with 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading.Primary power source shall be electricity but capable of using diesel fuel as a supplemental fuel.The waste incinerators shall be designed for 3 Phase, 380-400 V, 50 Hz electricity supply.Should have dual combustion chambers with gas temperature achieve 1000 C for retention time at least 2 second,Have a thermal efficiency of not less than 85%.All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or  otherwise treated against atmospheric and process induced corrosion.The incinerator combustion chambers should be designed for easy maintenance of all internal parts including the  refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also  be protected against oxidation, corrosion, etc.Primary and secondary chambers preferably have rounded inside corners to avoid the formation of dead zone or cold pockets.Generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.Achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%. Combustion Efficiency (CE) at least 99%.
1. Burning Capacity i. Incinerator should be capable to burn waste @ 100 kg / hr in single loading. 2. Construction i.   Packaged type skid mounted dual chamber construction ii. Stainless steel or Mild steel outer with thickness 5mm or more, sheet should be painted with heat resistant and anti-corrosive paint. iii. Internal surface of incinerator should be line with non– cracking refractory bricks made of ceramics or concrete to withstand the temperature of 1400 oC, furthermore bricks must be backed by thermal insulation and have thickness in between 220C250 mm. iv. There should be thermal insulation of high performance calcium silicate (Density 230Kg.m-3)to withstand high temperature with flame spread/smoke index not more than 1. v. Refractory and thermal insulation must be designed in robust way so that outer temperature on sheet does not rise above 55– 60 oC even after continuous operation of 12 hours. 3. Primary Chamber i. Chamber be designed with capacity to load 100kg medical waste with volume at least 1.2m3 or more, chamber must have separate door for loading of waste and for removal of ash using manual ash removing tool. ii. Pyrolytic burning mechanism with burning temperature not below than 900 oC. iii. Blower Centrifugal fan (according to manufacturer design) will be provided to inject air for burning waste and gases in primary combustion chamber furthermore air  regulation and distribution will be automatic and electronically controlled. iv.  Chamber should have electrically operated natural gas burner. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: sales@hiclover.comEmail: hicloversales@gmail.com   […]
Average 30kgs per hour ***Primary chamber(200Liters) *** Secondary chamber *** Mix combustion chamber *** Stainless steel chimney(1meter) *** Italy made oil burner(2sets) *** Dry Scrubber *** Weight 1.7T(can reduce to 1.0Ton) Main Spare Parts(Standard for incinerator, and price include already): *** 2 sets Italy Oil Burner *** 2sets Temperature Probe *** 1 set Control Case […]
HICLOVER Fighting COVID-19 CE ISO
HICLOVER Hot Blogs
Recent Posts