Oil Fired Incinerator
Basic Info.
Additional Info.
Product Description
Q: What is kind of waste can use in this equipment? A: This equipment for pet creature, medical waste, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year based on use.
Generally, we proposal customer purchase crematory based on animal size. For small creature, cats, birds match for small scale crematory (Model YD-15C/20C/30C). For large pets, like Alaskan Malamute dog, match for MID-scale crematory (Model A360, A600, A900). For additional large animals, match for model A1200, A1500, A2400, A4000.
Q: Assembly and Testing A: We provide all documents and incinerators easy to installation and functionality. Client can send individuals visit our factory to learn operation and installation. Generally, waste scale cost, waste to power sprinklers, incinerator capacity of 40 kg/hr, wat is the capacity of burner for the incinerator of 100kg/hr, water dusti filters, we don’t send engineer to local website if not ask. The dispatch cost is extra based on order. The next combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according model, use situation.
One individual can service 02 device incinerators. The staff should have fundamental electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation consumer guider, and know risk of waste to safeguard worker self with necessary security element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |