incinerators medical and infectious wastes

The oven is provided with supply burner, which turns on automatically when the 
temperature of the gas combustion, after the last air combustion injection, falls 
under the target temperature of 850 °C or 1.100 °C. The burner is used as well 
during the start and stop system operations, this is to guarantee a regular temperature 
of 850 °C or 1.100°C during these operations and as long as the waste material remains 
in the combustion chamber.
All burners have a non-stop ventilation system, to avoid damages to stoke wholes, 
openings), and to the deflector 
group, caused by high working temperatures they are exposed, when reached the 
fixed limit they go on stand-by. Burners are also provided with instruments for the 
pyrometric temperature check, 
to keep automatically the incineration oven and the post-combustion chamber to 
the fixed planned temperatures.
Particles removal system is a humid working installation, composed by a Scrubber 
connected through a pipe, fully covered with refractory material on the gas exit 
coming out form post-combustion chamber. The system turns on when the incineration oven comes 
into action and turns off once the planned cycle is complete. Particles purification 
occurs through water that sprinkled at high pressure, from special nozzles placed 
on the transit section, wets the fine particles held in the coming out fumes dragging them away.Capacity 100kg/Hr

Electricity Requirement AC 380V/220, 50 Hz
Method of Incineration Pyrolysis  Gasification Combustion
Waste Feeding Batch feeding type
moisture up to 80 %
WORKING DURATION FOR 8-16 HR CONTINIOUS
PLC TYPE CONTROL TYPE
COMBUSTION EFFICENCY  99%
waste charging door 
clinker door
clean out door 
ash trolley access door
Number of Combustion Stage Double stage
Target Waste Characteristics  (100% medical and infectious wastes generated in hospital) 1) Human Anatomical waste, Microbiological infectious waste, Non-Anatomical infectious wastes/Hospital
2) Low degree caloric value 4000-5000 cal/kg