Incinerator manufacturers china

It should have a Temperature indication and control center for each chamber
It should have a Fuel tank of capacity 200 liters ±20 liters
It should have a chimney stack of 6 to 8 meters. 
6mtrs will be used in the rural areas while 8mtrs will be used in the areas within the provincial town 
A minimum of 2 chambers 

Model

YD-100

Burning Rate

Average 100 kgs/hour

Feed Capacity

Average 200 kgs

Primary Combustion Chamber

1200 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

14--28 kg/hour

Gas Consumption (Natural Gas)

10--32.2 m3/hour

Internal Dimensions

130 x 100 x 90cm (primary chamber)

External Dimensions

220 x 180 x 360cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

60 x 120cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

7300 kgs

Operation Technical Specifications

Primary Chamber Temperature

800-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

The walls of each chamber should be constructed with high grade refractory brick of a thickness anywhere between 210 – 240mm 
Each chamber should have combustion burner air fans which are automatically controlled to ensure efficient heat distribution
Each chamber should have at least one temperature sensor
One temperature sensor mounting point at the base of the exit flue ensuring that chamber reaches the necessary 800°C minimum.
primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content.
“The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment.

All incinerators shall meet the following emission and operating standards:
• Combustion efficiency (C.E.) shall be at least 99.0%
• The combustion efficiency shall be computed as follows:
o C.E = (CO2 X 100) / (%CO2 +%CO)
Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.”